Meyerhofs Method

Courses > Foundation Analysis and Design > Bearing Capacity of Shallow Foundations > Meyerhofs Method

Introduction

In geotechnical engineering, bearing capacity is the capacity of soil to support the loads applied to the ground. The bearing capacity of soil is the maximum average contact pressure between the foundation and the soil which should not produce shear failure in the soil. Ultimate bearing capacity (qf) is the theoretical maximum pressure which can be supported without failure; allowable bearing capacity (qa) is the ultimate bearing capacity divided by a factor of safety. Sometimes, on soft soil sites, large settlements may occur under loaded foundations without actual shear failure occurring; in such cases, the allowable bearing capacity is based on the maximum allowable settlement.

» Try our free powerful online bearing capacity calculator «

There are three modes of failure that limit bearing capacity: general shear failure, local shear failure, and punching shear failure.

Note! Other methods proposed for bearing capacity of shallow foundations are: Terzaghi's bearing capacity method which is the earliest method proposed in 1943, and Brinch and Hansen (1970).

 


Concepts and Formulas

Meyerhof's bearing capacity theory:

Meyerhof (1963) proposed a formula for calculation of bearing capacity similar to the one proposed by Terzaghi but introducing further foundation shape coefficients.
He introduced a coefficient sq that multiplies the N factor, depth factors  di and inclination factors ii  depth factors di and inclination factors ii for the cases where the load line is inclined to the vertical. 

 

Meyerhof’s general bearing capacity equations

Note!  In all equations given below involving B and L, if there is eccentricity at the bearing elevation, use Beff in place of B and Leff in place of L, where Beff= B– 2eB, and Leff= L– 2eL. In the unusual case where L– 2eL< B– 2eB, use Beff= L– 2eand Leff= B– 2eB 

Meyerhof provided two general equations - one for the case when the resultant load at the bearing level (Qb) is vertical (no horizontal component), and one for the case when Qb is inclined from vertical (can be resolved into vertical and horizontal components) with the horizontal component of load in the direction of the width of the footing.

Vertical load:

Qb = c Nc Sc dc + q0 Nq Sq dq + 0.5 g B Ng Sg dg

Inclined load:

Qb = c Nc dc ic + q0 Nq dq iq + 0.5 g B Ng dg ig 

where q0 is the vertical stress at the bearing level outside the footprint of the foundation (called the surcharge pressure). qshould be the total vertical stress for total stress strength parameters, and the effective vertical stress for effective strength parameters. The value of to be used in the above equations depends on the depth of the groundwater table  relative to the depth of embedment of the foundation. See how ground water level can affect unit weight.

Meyerhof's bearing capacity factors

Nc, Nq, Nr:  Meyerhof’s bearing capacity factors depend on soil friction angle, f.

Nq = eptanf tan2(45+f/2)

Nc = cot f ( Nq – 1)

Ng = (Nq-1) tan (1.4f)

Sc, Sq, Sg: shape factors

dc, dq, dg: depth factors

ic, iq, ig: incline load factors

Friction angle

Shape factor

Depth factor

Incline load factors

Any f

Sc=1+0.2Kp(B/L)

dc=1+0.2ÖKp (D/B)

ic=iq=(1-q/90°)2

f = 0

Sq=Sg=1

dq=dg=1

ig=1

10°

Sq=Sg=1+0.1Kp(B/L)

dq=dg=1+0.1ÖKp (D/B)

ig=(1-q/f)2

 

C: Cohesion of soil

g: unit weight of soil (See how ground water level can affect it)

D: depth of footing

B, L: width and length of footing

K= tan2(45+f/2), passive pressure coefficient.

q = tan-1(Qh/Qv) = angle of the load in degrees

 

The table shown below can be used to approximately check your calculation of the main bearing capacity factors (Nc, Nq, and Ng) using Meyerhof’s method. It is, of course, better and more accurate to check it with our free online bearing capacity calculator for shallow foundations.

Table 1: Meyerhof’s bearing capacity factors

f

Nc

Nq

Nr

0

5.1

1

0

5

6.5

1.6

0.1

10

8.3

2.5

0.4

15

11

3.9

1.2

20

14.9

6.4

2.9

25

20.7

10.7

6.8

30

30.1

18.4

15.1

35

46.4

33.5

34.4

40

75.3

64.1

79.4

Figure 1: Meyerhof’s bearing capacity factors.

 

 


Watch Videos

 


Solved sample problems

Example 1: Strip footing on clayey sand (English units)

Given:

3 ft wide strip footing, bottom of footing at 2 ft below ground level

Requirement

Determine allowable soil bearing capacity using Meyerhof’s equation.

Solution:

Determine ultimate soil bearing capacity using Meyerhof’s bearing capacity equation for vertical load.

Passive pressure coefficient

Kpr = tan2(45+f/2) = tan2(45+25/2) = 2.5

 Shape factors:

Sc=1+0.2Kp(B/L) = 1+0.2*2.5*(0)=1

Sq=Sg=1+0.1Kp(B/L) = 1+0.1*2.5*(0) = 1

Depth factors:

Dc=1+0.2ÖKp (B/L) = 1+0.2*Ö2 (0) = 1

Dq=Dg=1+0.1ÖKp (D/B) = 1+0.1*Ö2.5 (3/3) = 1.16

From Table 1 or Figure 1, Nc = 20.7, Nq = 10.7, Nr = 6.8 for f = 25 degree

Qu = c Nc Sc Dc + g D Nq Sq Dq + 0.5 g B Ng Sg Dg

= 500*20.7*1*1 +100*3*10.7*1*1.16+0.5*100*3*6.8*1*1.16

=  15257 lbs/ft2

Allowable soil bearing capacity,

Qa = Qu / F.S. = 15257 / 3 = 5085 lbs/ft2 @ 5000 lbs/ft2

 

Example 2: Rectangular footing on sandy clay (English units)

Given:

8 ft by 4 ft rectangular footing, bottom of footing at 3 ft below ground level.

Requirement

Determine allowable soil bearing capacity using Meyerhof’s equation.

Solution:

Determine ultimate soil bearing capacity using Meyerhof’s bearing capacity equation for vertical load.

Passive pressure coefficient

Kpr = tan2(45+f/2) = tan2(45+20/2) = 2.

Shape factors:

Sc=1+0.2Kp(B/L) = 1+0.2*2*(4/8)=1.2

Sq=Sg=1+0.1Kp(B/L) = 1+0.1*2*(4/8) = 1.1

Depth factors:

Dc=1+0.2ÖKp (B/L) = 1+0.2*Ö2 (4/8) = 1.14

Dq=Dg=1+0.1ÖKp (D/B) = 1+0.1*Ö2 (3/4) = 1.1

From Table 1 or Figure 1, Nc = 14.9, Nq = 6.4, Nr = 2.9 for f = 20 degree

Qu = c Nc Sc Dc + g D Nq Sq Dq + 0.5 g B Ng Sg Dg

= 500*14.9*1.2*1.14 +100*3*6.4*1.1*1.1+0.5*100*4*2.9*1.1*1.1

=  13217 lbs/ft2

Allowable soil bearing capacity,

Qa = Qu / F.S. = 13217 / 3 = 4406 lbs/ft2 @ 4400 lbs/ft2

 

Example 3: Square footing with incline loads (English units)

Given:

8 ft by 8 ft square footing, bottom of footing at 3 ft below ground level.

Requirement

Determine allowable soil bearing capacity using Meyerhof’s equation.

Solution:

Determine ultimate soil bearing capacity using Meyerhof’s bearing capacity equation for vertical load.

Passive pressure coefficient

Kpr = tan2(45+f/2) = tan2(45+15/2) = 1.7

Shape factors:

Sc=1+0.2Kp(B/L) = 1+0.2*1.7*(8/8)=1.34

Sq=Sg=1+0.1Kp(B/L) = 1+0.1*1.7*(8/8) =1.17

Depth factors:

Dc=1+0.2ÖKp (B/L) = 1+0.2*Ö1.7 (8/8) = 1.26

Dq=Dg=1+0.1ÖKp (D/B) = 1+0.1*Ö1.7 (3/8) = 1.05

Incline load factors:

q = tan-1 (20/100) = 11.3°

Ic=Iq=(1-q/90°)2=(1-11.3/90)2= 0.76

Ig=(1-q/f)2=(1-11.3/15)2=0.06

From Table 1 or Figure 1, Nc = 11, Nq = 3.9, Nr = 1.2 for f = 15 degree

Qu = c Nc Sc Dc Ic + g D Nq Sq Dq Iq + 0.5 g B Ng Sg Dg Ig

= 500*11*1.34*1.26*0.76+100*3*3.9*1.17*1.05*0.76+0.5*100*8*1.17*1.05*0.06

=  8179 lbs/ft2

Allowable soil bearing capacity,

Qa = Qu / F.S. = 8179 / 3 = 2726 lbs/ft2 @ 2700 lbs/ft2

 


Download Files